Home >> Fiat >> 2015 >> 500 Turbo, Standard Trans >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> (Heating & Air Conditioning - Electrical Diagnostics - 500 - Except Electric) >> DTC Troubleshooting >> B1909-77-RECIRCULATION Door - Commanded Position Not Reachable >> Theory Of Operation

Theory Of Operation

After the initial installation of the A/C Heater Control, the controller is calibrated to each individual door actuator. The recirculation door actuator is connected to the A/C heater control or module by a dedicated two-wire lead and connector of the HVAC wire harness. When the A/C Heater Control pulls the voltage on one side of the control circuit high and the other low, the door actuator will move in one direction. When the A/C Heater Control reverses the polarity of the voltage to the motor, the recirculation door actuator moves in the opposite direction. When the recirculation air door reaches its travel limit, the A/C heater control will turn the voltage off. Unlike the mode and blend door actuators, the recirculation door does not use a position sensor due to the door only has two positions of either open or closed. The A/C Heater Control learns the recirculation door stop positions during the calibration procedure.