LEMON Manuals: Even more car manuals for everyone
Home >> Fiat >> 2014 >> 500c Abarth >> Repair and Diagnosis >> External Pages >> Different car >> Section 47 (Antilock Brake System (Abs) - Electrical Diagnostics - 500E) >> Diagnosis And Testing >> C0020-49-RECIRCULATION Pump - Internal Electronic Failure >> Diagnostic Test

Diagnostic Test

WARNING: This page is about a different car, the 2014 Fiat 500e. However, it is still accessible from the selected car via links, so may be relevant.
  1. VERIFY THE DTC IS ACTIVE 
    NOTE:

    This DTC must be active for the results of this test to be valid.

    1. Ignition on.
    2. With the scan tool, read and record DTCs.
    3. With the scan tool, read and record Freeze Fame information.
    4. With the scan tool, erase DTCs.
    5. Turn the ignition off. Remove the key from the Ignition Switch, close doors and allow the ABS Module to shut down.
      NOTE:

      Allow up to two minutes for the ABS Module to shut down. Opening the vehicle door will interrupt the shut down process.

    6. Ignition on, in Ready Mode.
    7. Press the brake pedal firmly and release.
    8. With the scan tool, read and record DTCs.

      Is the DTC active at this time?

      Yes 

      • Go To  2

      No 

  2. ANTI-LOCK BRAKE SYSTEM (ABS) 
    1. Perform any Technical Service Bulletins (TSBs) that may apply.
    2. Turn the ignition off. Remove the key from the Ignition Switch, close doors and allow the ABS Module to shut down.
      NOTE:

      Allow up to two minutes for the ABS Module to shut down. Opening the vehicle door will interrupt the shut down process.

    3. Inspect the related wiring harness. Look for any chafed, pierced, pinched, or partially broken wires.
    4. Inspect the related wire harness connectors. Look for broken, bent, pushed out, or corroded terminals.

      Were any problems found?

      Yes 

      No 

      NOTE:

      For this failure it is necessary to replace both the ABS Module and the HCU as a complete unit.