Diagnostic Test
WARNING: This page is about a different variant/trim than selected.
- CHECK TO SEE IF DTC P1CBF IS CURRENT
- CHECK THE (T820) CIRCUIT FOR AN OPEN
- Turn the ignition off to the lock position.
- Disconnect the TCM C1 harness connector.
- Disconnect the Smart Drive Unit (SDU) harness connector.
- Check the (T820) circuit for an open.
Was an open in the (T820) circuit found?
Yes
- Repair the (T820) circuit for an open.
- Perform the C635 DDCT TRANSMISSION VERIFICATION TEST. Refer to STANDARD PROCEDURE .
No
- Go To 3
- CHECK THE (T820) CIRCUIT FOR A SHORT TO GROUND
- Check the (T820) circuit for a short to ground.
Was a short to ground in the (T820) circuit found?
Yes
- Repair the (T820) circuit for a short to ground.
- Perform the C635 DDCT TRANSMISSION VERIFICATION TEST. Refer to STANDARD PROCEDURE .
No
- Go To 4
- Check the (T820) circuit for a short to ground.
- CHECK THE (T820) CIRCUIT FOR A SHORT TO VOLTAGE
- Check the (T820) circuit for a short to voltage.
Was a short to voltage in the (T820) circuit found?
Yes
- Repair the (T820) circuit for a short to voltage.
- Perform the C635 DDCT TRANSMISSION VERIFICATION TEST. Refer to STANDARD PROCEDURE .
No
- Using the schematics as a guide, check the Smart Drive Unit (SDU) pins, terminals, and connectors for corrosion, damage, or terminal push out. Pay particular attention to all power and ground circuits. If no problems are found, replace the SDU in accordance with the Service Information.
- Perform the C635 DDCT VERIFICATION TEST. Refer to STANDARD PROCEDURE .
- Check the (T820) circuit for a short to voltage.
- CHECK THE SDU OPERATION
- Turn the ignition off to the lock position.
- Reconnect the Smart Drive Unit (SDU) harness connector.
- Ignition on, engine not running.
- Monitor the voltage on the (T820) Feed back circuit in the TCM C1 harness connector.
- Using a fused jumper wire connected to the (T318) circuit in the TCM C1 harness connector, momentarily jumper the (T318) circuit to ground while monitoring the voltage on the (T820) Feed back circuit.
Was there a change in voltage on the (T820) Feed back circuit when the (T318) circuit was jumpered to ground?
Yes
- Using the schematics as a guide, check the Transmission Control Module (TCM) pins, terminals, and connectors for corrosion, damage, or terminal push out. Pay particular attention to all power and ground circuits. If no problems are found, replace and program the TCM in accordance with the Service Information.
- Perform the C635 DDCT VERIFICATION TEST. Refer to STANDARD PROCEDURE .
No
- Using the schematics as a guide, check the Smart Drive Unit (SDU) pins, terminals, and connectors for corrosion, damage, or terminal push out. Pay particular attention to all power and ground circuits. If no problems are found, replace the SDU in accordance with the Service Information.
- Perform the C635 DDCT VERIFICATION TEST. Refer to STANDARD PROCEDURE .
- CHECK THE WIRING AND CONNECTORS
- The conditions necessary to set this DTC are not present at this time.
- Using the schematics as a guide, inspect the wiring and connectors specific to this circuit.
- Wiggle the wires while checking for shorted and open circuits.
- With the scan tool, check the Event Data to help identify the conditions in which the DTC was set.
Were there any problems found?
Yes
- Repair as necessary.
- Perform the C635 DDCT TRANSMISSION VERIFICATION TEST. Refer to STANDARD PROCEDURE .
No
- Test Complete.