Diagnostic Test
WARNING: This page is about a different variant/trim than selected.
- CHECK TO SEE IF DTC P0968 IS CURRENT
- CHECK THE (F591) PPV-S (SHIFTER VALVE) SOLENOID FEED CIRCUIT OPEN
- Turn the ignition off to the lock position.
- Disconnect the TCM C2 harness connector.
- Disconnect the Electrohydraulic control unit C2 harness connector.
- Check the (F591) PPV-S (Shifter Valve) feed circuit for an open.
Was an open in the (F591) PPV-S (Shifter Valve) feed circuit found?
Yes
- Repair the (F591) PPV-S (Shifter Valve) feed circuit for an open.
- Perform the C635 DDCT TRANSMISSION VERIFICATION TEST. Refer to STANDARD PROCEDURE .
No
- Go To 3
- CHECK THE (T491) PPV-S (SHIFTER VALVE) SOLENOID RETURN CIRCUIT OPEN
- Check the (T491) PPV-S (Shifter Valve) return circuit for an open.
Was an open in the (T491) PPV-S (Shifter Valve) return circuit found?
Yes
- Repair the (T491) PPV-S (Shifter Valve) return circuit for an open.
- Perform the C635 DDCT TRANSMISSION VERIFICATION TEST. Refer to STANDARD PROCEDURE .
No
- Go To 4
- Check the (T491) PPV-S (Shifter Valve) return circuit for an open.
- CHECK THE PPV-S (SHIFTER VALVE) SOLENOID
- Measure the resistance of the PPV-S (Shifter Valve) solenoid
Is the resistance between 2.9 and 3.5 Ohms?
Yes
- Using the schematics as a guide, check the Transmission Control Module (TCM) pins, terminals, and connectors for corrosion, damage, or terminal push out. Pay particular attention to all power and ground circuits. If no problems are found, replace and program the TCM in accordance with the Service Information.
- Perform the C635 DDCT VERIFICATION TEST. Refer to STANDARD PROCEDURE .
No
- Replace the PPV-S (Shifter Valve) solenoid in accordance with the Service Information.
- Perform the C635 DDCT VERIFICATION TEST. Refer to STANDARD PROCEDURE .
- Measure the resistance of the PPV-S (Shifter Valve) solenoid
- CHECK THE WIRING AND CONNECTORS
- The conditions necessary to set this DTC are not present at this time.
- Using the schematics as a guide, inspect the wiring and connectors specific to this circuit.
- Wiggle the wires while checking for shorted and open circuits.
- With the scan tool, check the Event Data to help identify the conditions in which the DTC was set.
Were there any problems found?
Yes
- Repair as necessary.
- Perform the C635 DDCT TRANSMISSION VERIFICATION TEST. Refer to STANDARD PROCEDURE .
No
- Test Complete.