LEMON Manuals: Even more car manuals for everyone
Home >> Fiat >> 2012 >> 500 Pop, Standard Trans >> Repair and Diagnosis (Single Page) >> Accessories & Equipment >> Communication Devices >> Body Control Module (BCM) - DTCS B1000-44 To B1083-19 >> Diagnosis And Testing >> B1028-14-High Beams - Circuit Short To Ground Or Open >> Diagnostic Test

Diagnostic Test

  1. CHECK FOR AN INTERMITTENT CONDITION 
    1. Turn the ignition on.
    2. With the scan tool, clear all DTCs.
    3. Turn the High Beam Headlamps off.
    4. With the scan tool, read DTCs.

      Does the scan tool display this DTC as active?

      Yes 

      • Go To  2.

      No 

      • Test complete, the condition or conditions that originally set this DTC are not present at this time. Using the wiring diagrams as a guide, check all related splices and connectors for signs of water intrusion, corrosion, pushed out or bent terminals, and correct pin tension.
      • Refer to STANDARD PROCEDURE and perform the BODY VERIFICATION TEST.
  2. CHECK THE HIGH BEAM RELAY 
    1. Turn the ignition off.
    2. Remove the High Beam Relay and substitute it with a known good relay.
    3. Turn the ignition on.
    4. With the scan tool, read DTCs.

      Does the scan tool display DTC: B1028-14-HIGH BEAMS - CIRCUIT SHORT TO GROUND OR OPEN?

      Yes 

      • Go To  3.

      No 

      • Replace the High Beam Relay.
      • Refer to STANDARD PROCEDURE and perform the BODY VERIFICATION TEST.
  3. CHECK THE (L300) HIGH BEAM RELAY CONTROL CIRCUIT FOR A SHORT TO GROUND 
    1. Turn the ignition off.
    2. Remove the High Beam Relay.
    3. Disconnect the BCM C1 harness connector.
    4. Measure the resistance between ground and the (L300) High Beam Relay Control circuit.

      Is the resistance above 10k Ohms?

      Yes 

      • Go To  4.

      No 

      • Repair the short to ground in the (L300) High Beam Relay Control circuit.
      • Refer to STANDARD PROCEDURE and perform the BODY VERIFICATION TEST.
  4. CHECK THE (L300) HIGH BEAM RELAY CONTROL CIRCUIT FOR AN OPEN 
    1. Measure the resistance of the (L300) High Beam Relay Control circuit between the High Beam Relay and the BCM C1 harness connector.

      Is the resistance below 5.0 Ohms?

      Yes 

      No 

      • Repair the open in the (L300) High Beam Relay Control circuit.
      • Refer to STANDARD PROCEDURE and perform the BODY VERIFICATION TEST.