LEMON Manuals: Even more car manuals for everyone
Home >> Eagle >> 1996 >> Summit Base >> Repair and Diagnosis (Single Page) >> Brakes >> Mechanical - Hydraulic >> Disc Brakes & Drum Brakes >> Testing >> Proportioning Valve >> Pressure Test

Pressure Test

  1. Connect pressure gauges to input and output ports of proportioning valve. See Fig 1 . Bleed brake system. See procedures under BLEEDING BRAKE SYSTEM  .
    Fig 1: Connecting Pressure Gauges To Proportioning Valve (Typical)
    G92H00213Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
  2. Slowly depress brake pedal. Check readings on pressure gauges. Ensure output pressure begins to drop relative to input pressure at specified pressure range (split point). See SPLIT POINT PRESSURE SPECIFICATIONS table.
    SPLIT POINT PRESSURE SPECIFICATIONS

    Application psi (kg/cm2 )
    Hatchback 348-420 (25-30)
    Sedan 420-491 (30-35)
  3. Continue depressing brake pedal, and check readings on pressure gauges. See PROPORTIONING VALVE PRESSURE SPECIFICATIONS table. If fluid pressures or split point are not within specification, replace proportioning valve.
PROPORTIONING VALVE PRESSURE SPECIFICATIONS

Application Inlet Pressure psi (kg/cm2 ) (1) Outlet Pressure psi (kg/cm2 )
Hatchback 953 (67) 519-590 (37-42)
Sedan 1024 (72) 590-661 (42-47)
(1) Max. side-to-side pressure differential is 57 psi (4 kg/cm2 ).