Inspection Procedure 1 - No Scan Tool Communication With Any System
NOTE:
For wiring diagram, see the WIRING DIAGRAMS - 2.0L & 2.4L
article.
NOTE:
Possible causes are: defective connector or wiring harness.
- Using voltmeter, check voltage between ground and terminal No. 16 (Red/Black wire) on 16-pin data link connector. For data link connector location, See Figure . Battery voltage should exist.
- If battery voltage exists, go to step 4). If battery voltage does not exist, check for defective terminals or connections at connectors B-07, B-50 and B-75. See Fig 1 .
- If connector or terminals are defective, repair as necessary. If connectors and terminals are okay, check wiring harness between power supply and data link connector on Red/Black wire. See the WIRING DIAGRAMS - 2.0L & 2.4L article.
- Using ohmmeter, check for continuity between ground and terminals No. 4 (Black wire) and No. 5 (Black/White wire) on data link connector. Continuity should exist on both wires.
- If continuity exists, replace scan tool. If continuity does not exist, repair open ground circuit on Black wire or Black/White wire to data link connector.