LEMON Manuals: Even more car manuals for everyone
Home >> Dodge and Ram >> 2024 >> ProMaster 2500 Base >> Repair and Diagnosis >> External Pages >> Different car >> Section 48 (Electric Vehicle Control Unit Module (EVCU) - DTCS P0691-00 To P0A02-00) >> DTC Troubleshooting >> P0692-00 Cooling Fan 1 Control Circuit High >> Diagnostic Test

Diagnostic Test

WARNING: This page is about a different car, the 2024 RAM ProMaster EV. However, it is still accessible from the selected car via links, so may be relevant.
  1. READ AND RECORD DTCS AND ENVIRONMENTAL DATA - ERASE DTCS AND CHECK FOR DTC TO RETURN 
    WARNING:

    On vehicles equipped with the high voltage system, you must thoroughly read and follow all High Voltage Safety procedures. In addition, before performing any diagnostic or service procedure near a high voltage component, you must perform the High Voltage Power Down. Failure to follow these instructions may result in possible serious or fatal injury.

    Read the HIGH-VOLTAGE SAFETY PROCEDURES. Refer to  HIGH VOLTAGE SAFETY PROCEDURES  . 

    When the HIGH-VOLTAGE POWER-DOWN PROCEDURE is necessary. Refer to  VEHICLE HIGH VOLTAGE POWER DOWN  . 

    1. With the scan tool, read DTCs in all Electronic Control Units (ECUs) and record on the repair order.
    2. For future reference, with the scan tool, run and save a vehicle Scan Report and all related recorded data.
    3. With the scan tool, erase all DTCs.
    4. Turn the ignition off for a minimum of 10.0 seconds.
    5. Turn the ignition on.
    6. Using the When Monitored and Set Conditions above and recorded data, operate the vehicle in the conditions that set the DTC.
    7. With the scan tool, read DTCs.

      Did the DTC return?

      Yes 

      • Go To  2

      No 

  2. CHECK THE (K175) RADIATOR FAN CONTROL CIRCUIT FOR A SHORT TO VOLTAGE 
    1. Turn the ignition off.
    2. Disconnect the Cooling Fan Module harness connector.
    3. Turn the ignition on.
    4. Measure the voltage on the (K175) Radiator Fan Control circuit at the Cooling Fan Module harness connector.

      Is the voltage above 5.2 Volts?

      Yes 

      No 

      • Go To  3
  3. CHECK RELATED HARNESS CONNECTIONS 
    1. Disconnect all EVCU harness connectors.
    2. Disconnect all related in-line harness connections (if equipped).
    3. Disconnect the related component harness connectors.
    4. Inspect harness connectors, component connectors, and all male and female terminals for the following conditions:
      • Proper connector installation.
      • Damaged connector locks.
      • Corrosion.
      • Other signs of water intrusion.
      • Weather seal damage (if equipped).
      • Bent terminals.
      • Overheating due to a poor connection (terminal may be discolored due to excessive current draw).
      • Terminals that have been pushed back into the connector cavity.
      • Check for spread terminals and verify proper terminal tension.

      Repair any conditions that are found.

    5. Connect all EVCU harness connectors. Be certain that all harness connectors are fully seated and the connector locks are fully engaged.
    6. Connect all in-line harness connectors (if equipped). Be certain that all connectors are fully seated and the connector locks are fully engaged.
    7. Connect all related component harness connectors. Be certain that all connectors are fully seated and the connector locks are fully engaged.
    8. With the scan tool, erase DTCs.
    9. Test drive or operate the vehicle in accordance with the when monitored and set conditions.
    10. With the scan tool, read DTCs.

      Did the DTC return?

      Yes 

      No