Housing - Air Inlet
- If the foam seal on the top of the inlet housing is deformed or damaged, the seal must be replaced.
- Position the air inlet housing (3) onto the top of the HVAC housing.
- Install the two screws (2) that secure the air inlet housing to the HVAC housing and tighten to the proper specification. Refer to TORQUE SPECIFICATIONS .
- Install the two screws (1) within the air inlet housing opening to the HVAC housing and tighten to the proper specification. Refer to TORQUE SPECIFICATIONS .
- Connect the HVAC wire harness to the recirculation door actuator.
- Install the HVAC housing. Refer to HOUSING, HVAC, INSTALLATION .