Transducer, A/C Pressure: Removal
NOTE:
It is not necessary to discharge the refrigerant system to replace the A/C pressure transducer.
- Disconnect and isolate the negative battery cable.
- Disconnect the wire harness connector (3) from the A/C pressure transducer (2).
- Remove the A/C pressure transducer from the A/C line (1) and remove and discard the O-ring seal.