3.6L - DTCS P0335 To P0430
>>
DTC Troubleshooting
>>
P040B-Exhaust Gas RECIRCULATION Temperature Sensor 1 Circuit Performance
>>
Set Condition
Set Condition
The difference between the EGR Temperature Sensor and either the ECT Sensor reading or AAT Sensor reading is greater than 15°C (59°F).