Check Valve, Washer: Installation
- Position the washer system check valve (1) to the underside of the right cowl plenum cover/grille panel (2). Be certain that the flow direction arrow molded into the check valve body is oriented towards the washer nozzles.
- From the underside of the right cowl plenum cover/grille panel, connect the supply hose and the two washer nozzle hoses to the three barbed nipples of the check valve.
- Install the right cowl plenum cover/grille panel over the cowl plenum. Refer to COVER, COWL PANEL, INSTALLATION .