LEMON Manuals: Even more car manuals for everyone
Home >> Dodge and Ram >> 2023 >> ProMaster 2500 >> Repair and Diagnosis >> Accessories & Equipment >> Infotainment >> Radio Frequency Module (RF Hub) - DTCS B1001-21 To B1045-01 >> DTC Troubleshooting >> B1002-21 RKE Fob 2 - Signal Amplitude Minimum >> Theory Of Operation

Theory Of Operation

The RF Hub Module uses a transponder mode to query the key Fob for low battery state in keyed ignition systems. This is done after the Fob authentication is complete so that it does not impact the starting system timing. The Low Battery condition determination is the responsibility of the Fob. The RF Hub receives Fob Battery Low information by two methods: 1) If any Fob has a low battery condition during authentication for the Keyless-Go feature. 2) If any Fob reports a low battery condition within its Remote Keyless Entry (RKE) command to the RFHUB.

The RF Hub also monitors the rolling code synchronization with the RKE transceiver Fob. When the Fob is pressed over 1024 times, it loses synchronization with the rolling code. Re-syncing automatically takes place in the background after the vehicle has been started and driven above 5 mph. This happens once per ignition cycle above 5 mph to all Fobs located inside the vehicle, just in case one of the Fobs was de-activated during a Fob safe lock procedure.