Home >> Dodge and Ram >> 2020 >> Durango R/T, AWD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 21 (3.6L - DTCS P2166 To U01B0) >> DTC Troubleshooting >> P2317-Ignition Coil 6 Secondary Circuit - Insufficient Ionization >> When Monitored And Set Conditions

When Monitored And Set Conditions

WARNING: This page is about a different variant/trim than selected.

This diagnostic runs continuously when the following conditions are met:

Set Conditions: 

Default Actions: 

Possible Causes
FUSED ASD RELAY OUTPUT CIRCUIT OPEN/HIGH RESISTANCE
COIL CONTROL 6 CIRCUIT SHORTED TO GROUND
COIL CONTROL 6 CIRCUIT OPEN/HIGH RESISTANCE
SPARK PLUG
COIL ON PLUG
POWERTRAIN CONTROL MODULE (PCM)

Always perform the PRE-DIAGNOSTIC TROUBLESHOOTING PROCEDURE before proceeding. Refer to  PRE-DIAGNOSTIC TROUBLESHOOTING PROCEDURE  .