Valve, Short Runner: Installation
WARNING: This page is about a different variant/trim than selected.
NOTE:
Do not reuse the old Short Runner Valve (SRV) actuator O-ring seal (1).
- Install a new
SRV actuator rubber O-ring seal (1).
- Install the SRV actuator (2) and tighten bolts (1) to the proper specifications. Refer to TORQUE SPECIFICATIONS .
- Install the intake manifold. Refer to INSTALLATION .
- Connect the negative battery cable.