- VERIFY THE DTC IS ACTIVE
- CHECK THE (C7) BLOWER MOTOR SUPPLY CIRCUIT FOR A SHORT TO GROUND
- Turn the ignition off to the lock position.
- Disconnect the HVAC Module harness connector.
- Disconnect the Blower Motor Power Module C1 harness connector.
- Measure the resistance between ground and the (C7) Blower Motor Supply circuit.
Is the resistance below 100k Ohms?
Yes
- Repair the (C7) Blower Motor Supply circuit for a short to ground.
- Perform the HVAC VERIFICATION TEST. Refer to HVAC VERIFICATION TEST .
No
- Go To 3
- CHECK THE (C806) BLOWER MOTOR GROUND SIGNAL CIRCUIT FOR A SHORT TO GROUND
- Measure the resistance between ground and the (C806) Blower Motor Ground Signal circuit.
Is the resistance below 100k Ohms?
Yes
- Repair the (C806) Blower Motor Ground Signal circuit for a short to ground.
- Perform the HVAC VERIFICATION TEST. Refer to HVAC VERIFICATION TEST .
No
- Go To 4
- Measure the resistance between ground and the (C806) Blower Motor Ground Signal circuit.
- CHECK THE BLOWER MOTOR POWER MODULE
- Turn the ignition off to the lock position.
- Replace the Blower Motor Power Module in accordance to the Service Information. Refer to MODULE, POWER, FRONT BLOWER MOTOR, REMOVAL or MODULE, POWER, REAR BLOWER MOTOR, REMOVAL .
- Perform the HVAC VERIFICATION TEST. Refer to HVAC VERIFICATION TEST
.
Did this DTC reset performing the HVAC Verification Test?
Yes
- Replace and program the HVAC Module in accordance with the Service Information. Refer to MODULE, HVAC, REMOVAL .
- Perform the HVAC VERIFICATION TEST. Refer to HVAC VERIFICATION TEST .
No
- Test complete.
- CHECK THE WIRING AND CONNECTORS
- The conditions necessary to set the DTC are not present at this time.
- With the scan tool, check the Environmental Data to help identify the conditions in which the DTC was set.
- Using the wiring diagrams as a guide, check all related splices and connectors for signs of water intrusion, corrosion, pushed out or bent terminals, and correct pin tension.
- Wiggle the wiring and connectors while checking for shorted and open circuits.
Were there any problems found?
Yes
- Repair as necessary.
- Perform the HVAC VERIFICATION TEST. Refer to HVAC VERIFICATION TEST .
No
- Test complete.