LEMON Manuals: Even more car manuals for everyone
Home >> Dodge and Ram >> 2015 >> Durango SXT, RWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 208 ((HVAC - Electrical Diagnostics)) >> DTC Troubleshooting >> B1052-13-Rear Blend/Temperature Door Control - Circuit Open >> Diagnostic Test

Diagnostic Test

WARNING: This page is about a different car, the 2016 Dodge Durango. However, it is still accessible from the selected car via links, so may be relevant.
  1. CHECK IF DTC IS ACTIVE 
    1. Ignition on, engine not running.
    2. Using the scan tool, read HVAC DTCs.

      Is this DTC active?

      Yes 

      • Go To  3

      No 

      • Go To  2
  2. PERFORM HVAC ACTUATOR CALIBRATION TEST 
    1. Using the scan tool, perform the HVAC Actuator Calibration Test.

      Did this DTC change from Stored to Active while performing the HVAC Actuator Calibration Test?

      Yes 

      • Go To  3

      No 

      • Go To  6
  3. CHECK THE REAR BLEND DOOR DRIVER CIRCUIT FOR AN OPEN 
    1. Turn the ignition off to the lock position.
    2. Disconnect the Rear Blend Door Actuator harness connector.
    3. Measure the resistance of the Rear Blend Door Driver circuit between the A/C Heater Control C1 harness connector and the Rear Blend Door Actuator harness connector.

      Is the resistance above 1.0 Ohm?

      Yes 

      • Repair the Rear Blend Door Driver circuit for an open or high resistance.
      • Perform the HVAC VERIFICATION TEST. Refer to HVAC VERIFICATION TEST  .

      No 

      • Go To  4
  4. CHECK THE COMMON DOOR DRIVER CIRCUIT FOR AN OPEN 
    1. Measure the resistance of the Common Door Driver circuit between the A/C Heater Control C1 harness connector and the Rear Blend Door Actuator harness connector.

      Is the resistance above 1.0 Ohm?

      Yes 

      • Repair the Common Door Driver circuit for an open or high resistance.
      • Perform the HVAC VERIFICATION TEST. Refer to HVAC VERIFICATION TEST  .

      No 

      • Go To  5
  5. CHECK THE REAR BLEND DOOR ACTUATOR 
    1. Replace the Rear Blend Door Actuator in accordance with the Service Information. Refer to ACTUATOR, BLEND DOOR, REMOVAL .
    2. Using the scan tool, erase HVAC DTCs and perform the HVAC Actuator Calibration Test.

      Did this DTC reset?

      Yes 

      No 

  6. CHECK THE WIRING AND CONNECTORS 
    1. The conditions necessary to set the DTC are not present at this time.
    2. Using the scan tool, check the Environmental Data to help identify the conditions in which the DTC was set.
    3. Using the wiring diagrams as a guide, check all related splices and connectors for signs of water intrusion, corrosion, pushed out or bent terminals, and correct pin tension.
    4. Wiggle the wiring and connectors while checking for shorted and open circuits.

      Were there any problems found?

      Yes 

      No 

      • Test complete.