LEMON Manuals: Even more car manuals for everyone
Home >> Dodge and Ram >> 2009 >> Durango 4WD V8-4.7L >> Repair and Diagnosis >> Heating and Air Conditioning >> Testing and Inspection >> Symptom Related Diagnostic Procedures >> Blowers Not On High - Test Not Run

Blowers Not On High - Test Not Run






BLOWERS NOT ON HIGH - TEST NOT RUN

For a complete wiring diagram refer to the Wiring Information Electrical Diagrams.

- When Monitored:
When the Cooldown Test is executed.

- Set Condition:
If either the front blower speed was not set to high speed prior to starting the Cooldown Test or the front blower speed was changed from high speed to another setting after starting the Cooldown test.

Refer to B1079-CLIMATE CONTROL COOL DOWN TEST EXCESSIVE TIME (ATC AND MTC) for the diagnostic test procedure. B1079