LEMON Manuals: Even more car manuals for everyone
Home >> Dodge and Ram >> 2006 >> Magnum SXT, AWD >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> HVAC System (Service Information) >> Plumbing >> Standard Procedure >> Refrigerant System Recovery

Refrigerant System Recovery

WARNING: Refer to the applicable warnings and cautions for this system before performing the following operation (Refer to HEATING & AIR CONDITIONING/PLUMBING - WARNINGS)  and (Refer to HEATING & AIR CONDITIONING/PLUMBING - CAUTIONS) . Failure to follow the warnings and cautions could result in possible personal injury or death.
Fig 1: R-134a Refrigerant Recovery/Recycling/Charging Station
GC0001451Courtesy of DAIMLERCHRYSLER CORP.

An R-134a refrigerant recovery/recycling/charging station (1) that meets SAE standard J2210 must be used to recover the refrigerant from the R-134a refrigerant system. Refer to the operating instructions supplied by the equipment manufacturer for the proper care and use of this equipment.