Home >> Dodge and Ram >> 2003 >> Viper >> Repair and Diagnosis >> Engine Performance >> System >> Powertrain Diagnostic Procedures >> Diagnostic Information And Procedures >> DRIVEABILITY - Gas - Diagnostic Tests >> DTC P0351: Ignition Coil #1 Primary Circuit, DTC P0352: Ignition Coil #2 Primary Circuit, DTC P0353: Ignition Coil #3 Primary Circuit, DTC P0354: Ignition Coil #4 Primary Circuit, DTC P0355: Ignition Coil #5 Primary Circuit >> When Monitored and Set Condition:

When Monitored and Set Condition:

P0351-IGNITION COIL #1 PRIMARY CIRCUIT 

When Monitored: With battery voltage greater than 8 volts during engine cranking or greater than 12 volts with engine running, engine rpm less than 2016, and none of the coils in dwell when checked.

Set Condition: Peak current is not achieved with battery based dwell plus 1.5 msec of diagnostic offset. It takes less than 3 seconds during cranking or up to 6 seconds while running to set.

P0352-IGNITION COIL #2 PRIMARY CIRCUIT 

When Monitored: With battery voltage greater than 8 volts during engine cranking or greater than 12 volts with engine running, engine rpm less than 2016, and none of the coils in dwell when checked.

Set Condition: Peak current is not achieved with battery based dwell plus 1.5 msec of diagnostic offset. It takes less than 3 seconds during cranking or up to 6 seconds while running to set.

P0353-IGNITION COIL #3 PRIMARY CIRCUIT 

When Monitored: With battery voltage greater than 8 volts during engine cranking or greater than 12 volts with engine running, engine rpm less than 2016, and none of the coils in dwell when checked.

Set Condition: Peak current is not achieved with battery based dwell plus 1.5 msec of diagnostic offset. It takes less than 3 seconds during cranking or up to 6 seconds while running to set.

P0354-IGNITION COIL #4 PRIMARY CIRCUIT 

When Monitored: With battery voltage greater than 8 volts during engine cranking or greater than 12 volts with engine running, engine rpm less than 2016, and none of the coils in dwell when checked.

Set Condition: Peak current is not achieved with battery based dwell plus 1.5 msec of diagnostic offset. It takes less than 3 seconds during cranking or up to 6 seconds while running to set.

P0355-IGNITION COIL #5 PRIMARY CIRCUIT 

When Monitored: With battery voltage greater than 8 volts during engine cranking or greater than 12 volts with engine running, engine rpm less than 2016, and none of the coils in dwell when checked.

Set Condition: Peak current is not achieved with battery based dwell plus 1.5 msec of diagnostic offset. It takes less than 3 seconds during cranking or up to 6 seconds while running to set.