When Monitored and Set Condition:
When Monitored: When the ignition is on. (Customer Complaint: fuel gauge displays empty).
Set Condition: The Instrument Cluster monitors the fuel level sensor signal circuit for a resistance value between approximately 25 ohms to 1100 ohms. If the Cluster senses a resistance less than 25 ohms, this code will set.