Home >> Dodge and Ram >> 2003 >> SX R/T >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Body Diagnostic Procedures >> Diagnostic Information And Procedures >> Instrument Cluster - Symptoms >> Symptom: FUEL LEVEL SENSOR SHORT >> When Monitored and Set Condition:

When Monitored and Set Condition:

When Monitored: When the ignition is on. (Customer Complaint: fuel gauge displays empty).

Set Condition: The Instrument Cluster monitors the fuel level sensor signal circuit for a resistance value between approximately 25 ohms to 1100 ohms. If the Cluster senses a resistance less than 25 ohms, this code will set.