LEMON Manuals: Even more car manuals for everyone
Home >> Dodge and Ram >> 2003 >> Durango Base, 5.9 Z, RWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 75 (HVAC - Plumbing) >> Refrigerant >> Diagnosis And Testing- Refrigerant System Leaks >> System Low

System Low

WARNING: This page is about a different car, the 2003 Dodge Dakota. However, it is still accessible from the selected car via links, so may be relevant.
  1. Position the vehicle in a wind-free work area. This will aid in detecting small leaks.
  2. Bring the refrigerant system up to operating temperature and pressure. This is done by allowing the engine to run with the air conditioning system turned on for five minutes.
  3. With the engine not running, use a electronic R-134a leak detector and search for leaks. Because R-134a refrigerant is heavier than air, the leak detector probe should be moved slowly along the bottom side of all refrigerant lines, connector fittings and components.
  4. To inspect the evaporator coil for leaks, insert the electronic leak detector probe into the center instrument panel outlet and the floor duct outlet. Set the blower motor switch to the lowest speed position, and the mode control switch in the recirculation mode (Max-A/C).