Leak Detection Pump (LDP) switch operation is monitored immediately after a cold start with battery/ambient temperature 40-90°F (4.4-32.0°C) and engine coolant temperature within 10°F (-12.2°C) of battery/ambient temperature. DTC will set when state of LDP switch does not change when solenoid is energized.