LEMON Manuals: Even more car manuals for everyone
Home >> Dodge and Ram >> 2003 >> Durango Base, 5.9 Z, RWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 100 (HVAC - Plumbing) >> Plumbing >> Diagnosis And Testing - Refrigerant System Leaks >> System Empty

System Empty

WARNING: This page is about a different car, the 2004 Dodge Dakota. However, it is still accessible from the selected car via links, so may be relevant.
  1. Evacuate the refrigerant system to the lowest degree of vacuum possible (approx. 28 in Hg.). Determine if the system holds a vacuum for 15 minutes. If vacuum is held, a leak is probably not present. If system will not maintain vacuum level, proceed with this procedure.
  2. (2) Prepare a 0.284 Kg. (10 oz.) refrigerant charge to be injected into the system.
  3. Connect and dispense 0.284 Kg. (10 oz.) of refrigerant into the evacuated refrigerant system.
  4. Proceed to Step  2 of SYSTEM LOW  procedure.