System Empty
WARNING: This page is about a different car, the 2004 Dodge Dakota. However, it is still accessible from the selected car via links, so may be relevant.
- Evacuate the refrigerant system to the lowest degree of vacuum possible (approx. 28 in Hg.). Determine if the system holds a vacuum for 15 minutes. If vacuum is held, a leak is probably not present. If system will not maintain vacuum level, proceed with this procedure.
- (2) Prepare a 0.284 Kg. (10 oz.) refrigerant charge to be injected into the system.
- Connect and dispense 0.284 Kg. (10 oz.) of refrigerant into the evacuated refrigerant system.
- Proceed to Step 2 of SYSTEM LOW procedure.