Pressure Bleeding
Follow the manufacturer's instructions carefully when using pressure equipment. Do not exceed the tank manufacturer's pressure recommendations. Generally, a tank pressure of 15-20 psi is sufficient for bleeding. Fill the bleeder tank will recommended fluid and purge air from the tank from the tank lines before bleeding. Do not pressure bleed without a proper master cylinder adapter. The wrong adapter can lead to leakage, or drawing air back into the system. Use adapter provided with the equipment or Adapter (6921).