Calibration Test

CHEC-1 will be displayed in odometer window. Each of instrument cluster gauges will move sequentially through each calibration point. See GAUGE CALIBRATIONS  table. If gauge needle is not calibrated properly, a problem in instrument cluster exists. See BODY CONTROL COMPUTER TESTS in BODY CONTROL COMPUTER article for gauge recalibration procedures.

GAUGE CALIBRATIONS

Gauge Sequence Calibration Point
Speedometer
1 0 MPH (0 Km/h)
2 20 MPH (40 Km/h)
3 55 MPH (80 Km/h)
4 75 MPH (120 Km/h)
Tachometer
1 0 RPM
2 1000 RPM
3 3000 RPM
4 6000 RPM
Fuel Gauge
1 Empty
2 1/8 Full
3 1/4 Full
4 Full
Temperature Gauge
1 Cold
2 Low Normal
3 High Normal
4 Hot