WARNING: Disconnect battery and wait 2 minutes before proceeding.
  1. Disconnect driver-side air bag module. Connect a jumper between driver side air bag line 1 and 2. Turn ignition on. Reconnect battery. Use DRB to read active codes. If DRB shows DRIVER SQUIB CIRCUIT SHORTED, replace driver-side air bag module. If not, go to next step.
  2. Disconnect clockspring 2-way connector. Connect jumper between driver air bag line 1 and 2. Use DRB to read active codes. If DRB shows DRIVER SQUIB CIRCUIT SHORTED, replace clockspring. If not, go to next step.
  3. Disconnect battery and wait 2 minutes before proceeding. Remove jumper. Disconnect ACM 4-way connector. Use Ohmmeter to measure driver-side air bag line 1 circuit between ACM 4-way connector and clockspring 2-way connector. If resistance is below 1 ohm, go to next step. If not, repair open or high resistance in driver-side airbag line 1 circuit.
  4. Measure driver-side air bag line 2 circuit between ACM 4-way connector and clockspring 2-way connector. If resistance is above 5.0 ohms, repair open or high resistance in driver-side airbag line 2 circuit. If resistance is below 1 ohm, perform TEST 15A - ACM REPLACEMENT PROCEDURE  .