Home >> Chrysler >> 2014 >> 200 Limited, 2D Convertible >> Repair and Diagnosis (Single Page) >> Accessories & Equipment >> Communication Devices >> (Cabin Compartment Node (CCN) - Electrical Diagnostics) >> DTC Troubleshooting >> B1806-Passenger Door Lock/Unlock Switch Circuit Low >> Diagnostic Test

Diagnostic Test

  1. TEST FOR INTERMITTENT CONDITION 
    1. With the scan tool, record and erase the DTCs
    2. Operate the Passenger Door Lock Switch in all positions several times.
    3. Cycle the ignition from on to off.
    4. Turn the ignition on.
    5. With the scan tool, read the DTCs.

      Does the scan tool display B1806-PASSENGER DOOR LOCK/UNLOCK SWITCH CIRCUIT LOW?

      Yes 

      • Go To  2

      No 

      • The conditions that caused this code to set are not present at this time. Using the wiring diagram/schematic as a guide, inspect the wiring and connectors.
      • Perform the BODY VERIFICATION TEST. Refer to STANDARD PROCEDURE .
  2. PASSENGER DOOR LOCK SWITCH SHORTED 
    Fig 1: Checking Passenger Door Lock Switch For A Short
    GC0124227Courtesy of CHRYSLER GROUP, LLC
    1. With the scan tool, erase the DTCs.
    2. Disconnect the Passenger Window/Door Lock Switch connector.
    3. With the scan tool, read the DTCs.

      Does the scan tool display B1806-PASSENGER DOOR LOCK/UNLOCK SWITCH CIRCUIT LOW?

      No 

      • Replace the Passenger Window/Door Lock Switch.
      • Perform the BODY VERIFICATION TEST. Refer to STANDARD PROCEDURE .

      Yes 

      • Go To  3
  3. (P696) PASSENGER DOOR LOCK SWITCH MUX CIRCUIT SHORT TO GROUND 
    Fig 2: Checking Passenger Door Lock Switch MUX Circuit For Short To Ground
    GC0124229Courtesy of CHRYSLER GROUP, LLC
    1. Turn the ignition off.
    2. Disconnect the Cluster C2 connector.
    3. Measure the resistance between ground and the (P696) Passenger Door Lock Switch Mux circuit.

      Is the resistance below 10, 000.0 ohms?

      Yes 

      • Repair the (P696) Passenger Door Lock Switch Mux circuit for a short to ground.
      • Perform the BODY VERIFICATION TEST. Refer to STANDARD PROCEDURE .

      No 

      • Replace the Instrument Cluster in accordance with the Service Information.
      • Perform the BODY VERIFICATION TEST. Refer to STANDARD PROCEDURE .