Gear disengagement: A failure is detected during gear disengagement if three or more pressure regulators are activated at the same time for a calibrated amount of time.
Engaged position Neutral or Park: A failure is detected while Neutral or Park position is engaged if in addition to the two pressure regulators a third pressure regulator is activated at the same time for a calibrated amount of time.