Diagnostic Test
- ACTIVE DIAGNOSTIC TROUBLE CODE (DTC) NOTE:
Diagnose any Misfire DTCs before continuing.
- Turn the ignition on.
- With a scan tool, read the DTCs.
Is the DTC active at this time?
Yes
- Go To 2.
No
- Refer to STANDARD PROCEDURE and perform the INTERMITTENT CONDITION diagnostic procedure.
- CHECKING THE MDS SOLENOID CONTROL CIRCUIT BETWEEN THE C101 IN-LINE HARNESS CONNECTOR AN THE PCM NOTE:
The DTC must not be active for the actuator test to operate properly, clear all DTC before continuing.
- Turn the ignition off.
- Disconnect the C101 harness connector located behind the left side cylinder head.
- Using a 12-volt test light, jump from the Ground circuit to the (K451) MDS Solenoid No. 1 Control circuit in the C101 harness connector (PCM side).
- Turn the ignition on.
- Using the scan tool, actuate the MDS Solenoid No. 1.
Does the 12-volt test light flash on and off?
Yes
- Go To 3.
No
- Go To 4.
- MDS SOLENOID RESISTANCE
- Turn the ignition off.
- Measure the resistance between the Ground circuit and the (K451) MDS Solenoid No. 1 Control circuit in the C101 harness connector (MDS side).NOTE:
It is important to follow the below temp/resistance values to ensure an accurate reading.
MDS SOLENOID RESISTANCE TEMPERATURE VALUE RESISTANCE - MINIMUM RESISTANCE - MAXIMUM -18° C (0° F) 7.22 ? 8.12 ? 0° C (32° F) 7.92 ? 8.82 ? 20° C (68° F) 8.72 ? 9.62 ? 38° C (100° F) 9.42 ? 10.32 ? 66° C (150° F) 10.62 ? 11.52 ? 93° C (200° F) 11.82 ? 12.72 ? 121° C (250° F) 12.82 ? 13.72 ? 149° C (300° F) 14.02 ? 14.92 ? Is the resistance within an acceptable range?
Yes
- Go To 12.
No
- Go To 8.
- GROUND CIRCUIT OPEN (PCM SIDE)
- Turn the ignition off.
- Using a 12-volt test light connected to the 12 volts, probe the Ground circuit in the C101 harness connector (PCM side).
Does the test light illuminate brightly?
Yes
- Go To 5.
No
- Repair the open in the Ground circuit.
- Refer to STANDARD PROCEDURE and perform the POWERTRAIN VERIFICATION TEST.
- (K451) MDS SOLENOID NO. 1 CONTROL CIRCUIT SHORTED TO BATTERY VOLTAGE (PCM SIDE)
- Disconnect the PCM C2 harness connector.
- Turn the ignition on.
- Measure the voltage on the (K451) MDS Solenoid No. 1 Control circuit in the C101 harness connector (PCM side).
Does the Voltmeter indicate voltage present?
Yes
- Repair the short to battery voltage in the (K451) MDS Solenoid No. 1 Control circuit between the PCM C2 harness connector and C101 harness connector.
- Refer to STANDARD PROCEDURE and perform the POWERTRAIN VERIFICATION TEST.
No
- Go To 6.
- (K451) MDS SOLENOID NO. 1 CONTROL CIRCUIT SHORTED TO GROUND (PCM SIDE)
- Turn the ignition off.
- Measure the resistance between ground and the (K451) MDS Solenoid No. 1 Control circuit in the C101 harness connector (PCM side).
Is the resistance below 100 Ohms?
Yes
- Repair the short to ground in the (K451) MDS Solenoid No. 1 Control circuit between the PCM harness connector and the C101 harness connector.
- Refer to STANDARD PROCEDURE and perform the POWERTRAIN VERIFICATION TEST.
No
- Go To 7.
- (K451) MDS SOLENOID NO. 1 CONTROL CIRCUIT OPEN (PCM SIDE)
- Measure the resistance of the (K451) MDS Solenoid No. 1 Control circuit from the C101 harness connector to the PCM C2 harness connector.
Is the resistance below 5.0 Ohms?
Yes
- Replace and program the Powertrain Control Module in accordance with the service information. Refer to MODULE, POWERTRAIN CONTROL, REMOVAL .
- Refer to STANDARD PROCEDURE and perform the POWERTRAIN VERIFICATION TEST.
No
- Repair the open in the (K451) MDS Solenoid No. 1 Control circuit between the C101 harness connector and the PCM C2 harness connector.
- Refer to STANDARD PROCEDURE and perform the POWERTRAIN VERIFICATION TEST.
- Measure the resistance of the (K451) MDS Solenoid No. 1 Control circuit from the C101 harness connector to the PCM C2 harness connector.
- GROUND CIRCUIT OPEN (MDS SIDE)
- Turn the ignition off.
- Gain access to the MDS Solenoid. Refer to SOLENOID, MULTIPLE DISPLACEMENT [ESG], REMOVAL .
- Disconnect the MDS harness connector.
- Measure the resistance of the Ground circuit between the C101 harness connector and the MDS 1 harness connector.
Is the resistance below 5.0 Ohms?
Yes
- Go To 9.
No
- Repair the open in the Ground circuit.
- Refer to STANDARD PROCEDURE and perform the POWERTRAIN VERIFICATION TEST.
- (K451) MDS SOLENOID NO. 1 CONTROL CIRCUIT SHORTED TO BATTERY VOLTAGE (MDS SIDE)
Courtesy of CHRYSLER GROUP, LLC
- Turn the ignition on.
- Measure the voltage on the (K451) MDS Solenoid No. 1 Control circuit in the MDS Solenoid No. 1 harness connector.
Does the Voltmeter indicate voltage present?
Yes
- Repair the short to battery voltage in the (K451) MDS Solenoid No. 1 Control circuit between the C101 harness connector and the MDS 1 harness connector.
- Refer to STANDARD PROCEDURE and perform the POWERTRAIN VERIFICATION TEST.
No
- Go To 10.
- (K451) MDS SOLENOID NO. 1 CONTROL CIRCUIT SHORTED TO GROUND (MDS SIDE)
- Turn the ignition off.
- Measure the resistance between ground and the (K451) MDS Solenoid No. 1 Control circuit in the MDS Solenoid 1 harness connector.
Is the resistance below 100 Ohms?
Yes
- Repair the short to ground in the (K451) MDS Solenoid No. 1 Control circuit between the C101 harness connector and the MDS harness connector.
- Refer to STANDARD PROCEDURE and perform the POWERTRAIN VERIFICATION TEST.
No
- Go To 11.
- (K451) MDS SOLENOID NO. 1 CONTROL CIRCUIT OPEN (MDS SIDE)
- Measure the resistance of the (K451) MDS Solenoid No. 1 Control circuit from the MDS Solenoid No. 1 harness connector to the C101 harness connector.
Is the resistance below 5.0 Ohms?
Yes
- Replace the MDS Solenoid in accordance with the Service Information. Refer to SOLENOID, MULTIPLE DISPLACEMENT [ESG], REMOVAL .
- Refer to STANDARD PROCEDURE and perform the POWERTRAIN VERIFICATION TEST.
No
- Repair the open in the (K451) MDS Solenoid No. 1 Control circuit between the C101 harness connector and the MDS harness connector.
- Refer to STANDARD PROCEDURE and perform the POWERTRAIN VERIFICATION TEST.
- Measure the resistance of the (K451) MDS Solenoid No. 1 Control circuit from the MDS Solenoid No. 1 harness connector to the C101 harness connector.
- CHECKING HARNESS CONNECTOR C101 AND GROUND CONNECTION
- Inspect the C101 harness connector.
- Make sure the ground terminal and control terminal are fastened securely into the connector and there are no signs of corrosion or damage.
- Check wiring to terminal connection. Look for an internal broken wire under the insulation.
- Inspect the Ground for a tight, clean connection.
Were any problems found?
Yes
- Repair as necessary.
- Refer to STANDARD PROCEDURE and perform the POWERTRAIN VERIFICATION TEST.
No
- Refer to STANDARD PROCEDURE and perform the INTERMITTENT CONDITION diagnostic procedure.