LEMON Manuals: Even more car manuals for everyone
Home >> Chrysler >> 2012 >> 300 C, 4WD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 17 (6.4L - DTCS P0522 To P1521) >> Diagnosis And Testing >> P1004-Short Runner Valve Control Performance >> Possible Causes

Possible Causes

WARNING: This page is about a different variant/trim than selected.
Possible Causes
(F342) ASD RELAY OUTPUT CIRCUIT OPEN OR HIGH RESISTANCE
HIGH RESISTANCE IN THE (K237) SHORT RUNNER VALVE (SRV) SIGNAL CIRCUIT
HIGH RESISTANCE IN THE (K238) SHORT RUNNER VALVE (SRV) CONTROL CIRCUIT
HIGH RESISTANCE IN THE (Z903) SHORT RUNNER VALVE (SRV) GROUND CIRCUIT
SHORT RUNNER VALVE (SRV) ASSEMBLY
POWERTRAIN CONTROL MODULE (PCM)

Always perform the Pre-Diagnostic Troubleshooting procedure before proceeding. Refer to  STANDARD PROCEDURE  .