WARNING: This page is about a different car, the 2015 RAM 3500 HD and 2015 RAM 2500 HD. However, it is still accessible from the selected car via links, so may be relevant.

The Cooled EGR Valve Assembly contains an electric DC motor and a gear box. An eccentric drive translates the gearbox output from a rotating motion (DC motor) to a linear stroke (output shaft). The full range of travel of the shaft is approximately 7.0 mm from a fully closed to fully open position. An internal return spring ensures that the valve returns back to its closed position as a fail safe.

There is a position sensor located on the output shaft. The sensor operates as a typical three wire sensor, with a 5-Volt Supply, Sensor Signal, and Sensor Ground circuit. Full range of travel of the output shaft will result in a change of approximately 3.0 volts in the position sensor reading. During normal operation the sensor signal will range between approximately 1.0 volts and 4.0 volts.

NOTE:

See the figures below for a typical current draw on the DC motor and voltage reading of the sensor during the EGR Valve opening and closing. The red line represents current draw of the DC motor and the black line represents the sensor voltage.

Fig 1: EGR Response During Opening Graph
GC0161559Courtesy of CHRYSLER GROUP, LLC
Fig 2: EGR Response During Closing Graph
GC0161558Courtesy of CHRYSLER GROUP, LLC