Diagnostic Test
WARNING: This page is about a different car, the 2015 RAM 3500 HD and 2015 RAM 2500 HD. However, it is still accessible from the selected car via links, so may be relevant.
- CHECK FOR RELATED DTCS
- Ignition on.
- Using the scan tool, read HVAC DTCs.
Are there any Door Control Circuit Open, Performance, or Short to Ground or Voltage DTCs present?
Yes
- Perform the appropriate diagnostic procedure.
Refer to DIAGNOSIS AND TESTING .
No
- Go To 2
- Perform the appropriate diagnostic procedure.
- CHECK FOR AN ACTIVE DTC
- With the scan tool, read HVAC DTCs and record on the repair order.
- Record the Environmental Data.
- With the scan tool, erase DTCs.
- Using the recorded Environmental Data, along with the When Monitored and Set Conditions above, operate the vehicle in the conditions that set the DTC.
- With the scan tool, read HVAC DTCs.
Did the DTC return?
Yes
- Go To 4
No
- Go To 3
- PERFORM HVAC ACTUATOR CALIBRATION TEST
- CHECK THE RECIRCULATION DOOR
- Remove the Recirculation Door Actuator and check the Recirculation Door for binding and full travel. Refer to ACTUATOR, RECIRCULATION DOOR, REMOVAL
.
Were any problems found?
Yes
- Repair or replace the Recirculation Door as necessary in accordance with the Service Information. Refer to HOUSING, HVAC, REMOVAL .
- Perform the HVAC VERIFICATION TEST. Refer to STANDARD PROCEDURE .
No
- Go To 5
- Remove the Recirculation Door Actuator and check the Recirculation Door for binding and full travel. Refer to ACTUATOR, RECIRCULATION DOOR, REMOVAL
.
- CHECK THE RECIRCULATION DOOR ACTUATOR
- Replace the Recirculation Door Actuator in accordance with the Service Information. Refer to ACTUATOR, RECIRCULATION DOOR, REMOVAL .
- Using the scan tool, erase HVAC DTCs.
- Using the scan tool, perform the HVAC ACTUATOR CALIBRATION TEST.
Did this DTC reset during HVAC ACTUATOR CALIBRATION TEST?
Yes
- Replace and program the A/C Heater Control in accordance with the Service Information. Refer to CONTROL, A/C AND HEATER, REMOVAL .
- Perform the HVAC VERIFICATION TEST. Refer to STANDARD PROCEDURE .
No
- Test complete.
- Perform the HVAC VERIFICATION TEST. Refer to STANDARD PROCEDURE .
- CHECK THE WIRING AND CONNECTORS
- The conditions necessary to set the DTC are not present at this time.
- Using the scan tool, check the Environmental Data to help identify the conditions in which the DTC was set.
- Using the wiring diagrams as a guide, check all related splices and connectors for signs of water intrusion, corrosion, pushed out or bent terminals, and correct pin tension.
- Wiggle the wiring and connectors while checking for shorted and open circuits.
Were any problems found?
Yes
- Repair as necessary.
- Perform the HVAC VERIFICATION TEST. Refer to STANDARD PROCEDURE .
No
- Test complete.