LEMON Manuals: Even more car manuals for everyone
Home >> Chrysler >> 2011 >> 300 C, RWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 78 (3.7L/4.7L/5/7L - DTCS P2174 To U1449 - NGC - 1500 & 2500) >> Diagnosis and Testing >> P2503-Charging System Output Low >> Diagnostic Test

Diagnostic Test

WARNING: This page is about a different car, the 2011 RAM Pickup. However, it is still accessible from the selected car via links, so may be relevant.
  1. ACTIVE DTC 
    NOTE:

    The battery must be fully charged.

    1. Ignition on, engine not running.
    2. With the scan tool, select View DTCs.
    3. Read and record the related Freeze Frame data and DTCs.
    4. With the scan tool, erase DTCs.
    5. Start the engine.
    6. Allow the idle to stabilize.
    7. Ignition on, engine not running.
    8. With the scan tool, select View DTCs.

      Is the DTC Active at this time?

      Yes 

      • Go To  3.

      No 

  2. VISUAL INSPECTION 
    WARNING:

    When the engine is operating, do not stand in direct line with the fan. Do not put your hands near the pulleys, belts or fan. Do not wear loose clothing. Failure to follow these instructions may result in possible serious or fatal injury.

    NOTE:

    Inspect the vehicle for aftermarket accessories that may exceed the Generator System output.

    NOTE:

    The Generator belt tension and condition must be checked before continuing.

    Visually inspect the engine for any of the following conditions:

    • Worn serpentine belt. Refer to BELT, Serpentine , Diagnosis and Testing .
    • Binding Engine-Driven accessories: A/C Compressor, P/S Pump, Water pump.
    • Misalignment of the Water pump, P/S Pump and A/C Compressor pulleys.
    • Corroded PCM power and ground circuits.

    Were any of the above conditions present?

    Yes 

    No 

    • Go To  3.
  3. FUSED B+ CIRCUIT HIGH RESISTANCE 
    WARNING:

    When the engine is operating, do not stand in direct line with the fan. Do not put your hands near the pulleys, belts or fan. Do not wear loose clothing. Failure to follow these instructions may result in possible serious or fatal injury.

    1. Perform a voltage drop test between the Generator B+ Output Terminal and the Battery + Post.

      Is the voltage above 0.4 of a Volt?

      Yes 

      • Repair the excessive resistance in the battery positive circuit between the Generator and Battery.
      • Perform the POWERTRAIN VERIFICATION TEST. Refer to POWERTRAIN VERIFICATION TEST .

      No 

      • Go To  4.
  4. GENERATOR OPERATION 
    Fig 1: Using 12-volt Test Light Connected To Ground To Probe (K20) Generator Field Control Circuit In Generator Field Harness Connector
    GC0090868Courtesy of CHRYSLER LLC
    1. Turn the ignition off.
    2. Disconnect the Generator Field harness connector.
    3. Using a 12-volt test light connected to ground, probe (K20) Generator Field Control circuit in the Generator Field harness connector.
      NOTE:

      The DTC needs to be cleared before actuating the Solenoid, if the DTC is not cleared, the Solenoid may not be allowed to actuate.

    4. Ignition on, engine not running.
    5. With the scan tool, actuate the Generator Field Driver.
      NOTE:

      The test light should be illuminated and bright proportional to the maximum duty cycle allowed by the scan tool. For example, if the scan tool allows 100% actuation, the brightness should be as bright as a direct connection to the battery. If the scan tool allows a maximum 25% actuation, the brightness should be 25% as bright as a direct connection to the battery.

      Does the test light illuminate accordingly during the actuation?

      Yes 

      • Verify that there is good pin to terminal contact in the Generator and Powertrain Control Module connectors. Replace the Generator if no problems were found with the connectors. Refer to GENERATOR , Removal .
      • Perform the POWERTRAIN VERIFICATION TEST. Refer to POWERTRAIN VERIFICATION TEST .

      No 

      • Go To  5.
  5. POWERTRAIN CONTROL MODULE (PCM) 
    1. Using the wiring diagram/schematic as a guide, inspect the wiring and connectors between the Generator and the Powertrain Control Module (PCM).
    2. Look for any chafed, pierced, pinched or partially broken wires.
    3. Look for broken, bent, pushed out or corroded terminals. Verify that there is good pin to terminal contact in the Generator and Powertrain Control Module connectors.
    4. Perform any Technical Service Bulletins that may apply.

      Were there any problems found?

      Yes 

      No