LEMON Manuals: Even more car manuals for everyone
Home >> Chrysler >> 2011 >> 300 C, RWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 510 (3.6L - DTCS P2161 To U1418) >> Diagnosis And Testing >> P2504-Charging System Output High >> Set Condition

Set Condition

WARNING: This page is about a different car, the 2013 Dodge Avenger and 2013 Chrysler 200. However, it is still accessible from the selected car via links, so may be relevant.

The alternator B+ voltage sense circuit voltage reading exceeds the direct Battery B+ sense circuit. The Generator Output terminal is not connected to the Battery B+ post. One trip fault.