LEMON Manuals: Even more car manuals for everyone
Home >> Chrysler >> 2011 >> 300 C, RWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 488 ((Totally Integrated Power Module (TIPM) - Electrical Diagnostics)) >> DTC Troubleshooting >> B2104-Ignition Run/Start Control Circuit Low >> Diagnostic Test

Diagnostic Test

WARNING: This page is about a different car, the 2013 Dodge Avenger and 2013 Chrysler 200. However, it is still accessible from the selected car via links, so may be relevant.
  1. CHECK FOR ACTIVE DIAGNOSTIC TROUBLE CODE (DTC) 
    1. Check all fuses.
    2. With the scan tool, read the active DTCs.
    3. Cycle the ignition switch from off to on, leaving the ignition off for a minimum of 30 seconds.
    4. With the scan tool, read the active DTCs.

      Does the scan tool display this DTC as active?

      Yes 

      • Go To  2

      No 

      • If the DTC is stored, check for an intermittent condition. Using the wiring diagram/schematic as a guide, visually inspect the related wiring harness connectors. Look for broken, bent, pushed out or corroded terminals.
      • Perform the BODY VERIFICATION TEST. Refer to STANDARD PROCEDURE .
  2. CHECK (F200) CIRCUIT FOR A SHORT TO GROUND 
    1. Turn the ignition off.
    2. Remove fuse number 28.
    3. Turn the ignition on.
    4. With the scan tool, read DTCs.

      Did the DTC changed from active to stored?

      Yes 

      • Go To  3

      No 

      • Go To  5
  3. ORC INTERNAL SHORT 
    WARNING:

    To avoid possible serious or fatal injury, turn the ignition off, disconnect the battery and wait two minutes before proceeding.

    1. Disconnect the ORC C2 harness connector.
    2. Reinstall fuse number 28.
    3. Turn the ignition on.
    4. Reconnect the battery.
    5. With the scan tool, read DTCs.

      Does the scan tool display this DTC as active?

      Yes 

      • Go To  4

      No 

  4. (F200) FUSED IGNITION SWITCH OUTPUT (RUN-START) CIRCUIT SHORTED TO GROUND 
    1. Turn the ignition off.
    2. Disconnect the TIPM C7 harness connector.
    3. Measure the resistance between ground and the (F200) Fused Ignition Switch Output (Run-Start) circuit.

      Is the resistance below 10k Ohms?

      Yes 

      • Repair the (F200) Fused Ignition Switch Output (Run-Start) circuit for a short to ground.
      • Perform the BODY VERIFICATION TEST. Refer to STANDARD PROCEDURE .

      No 

  5. CHECK TIPM FOR AN INTERNAL SHORT 
    1. Turn the ignition off.
    2. Disconnect the TIPM C11 harness connector.
    3. With the scan tool, read DTCs.

      Did the DTC changed from active to stored?

      Yes 

      • Go To  6

      No 

  6. CHECK COMPONENT FOR AN INTERNAL SHORT 
    NOTE:

    The (F202) circuit is the power supply for multiple modules.

    1. Turn the ignition off.
    2. Reconnect the TIPM C11 harness connector.
    3. Using the wiring diagrams as a guide, disconnect each component that is fed by the (F202) circuit one at a time while checking for the DTC to become stored.
    4. With the scan tool, read DTCs.

      Did the DTC changed from active to stored?

      Yes 

      • Replace the shorted component in accordance with the Service Information.
      • Perform the BODY VERIFICATION TEST. Refer to STANDARD PROCEDURE .

      No 

      • Repair the (F202) Fused Ignition Switch Output (Run-Start) circuit for a short to ground.
      • Perform the BODY VERIFICATION TEST. Refer to STANDARD PROCEDURE .