LEMON Manuals: Even more car manuals for everyone
Home >> Chrysler >> 2011 >> 300 C, RWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 42 (Power Distribution) >> OUTLET, Power, 115 V >> Diagnosis and Testing >> Diagnosis And Testing - 115 V Power Outlet

Diagnosis And Testing - 115 V Power Outlet

WARNING: This page is about a different car, the 2011 RAM Pickup and 2011 RAM Cab & Chassis. However, it is still accessible from the selected car via links, so may be relevant.
WARNING:

Be sure to utilize the proper safety gloves rated at least at a 00 rating when working on any high voltage system. Failure to do so may result in serious or fatal injury.

Proper use and care of rubber insulating gloves and sleeves are essential to user safety. Do not wear rings, watches, jewelry and sharp objects on your hands or arms, they will cause damage to the rubber gloves and sleeves.

NOTE:

Before attempting any repair on a inverter circuits, check for Diagnostic Trouble Codes with the scan tool.

NOTE:

B (+) range must be with 11.5 V DC to 16 V DC for inverter operation.

For complete circuit diagrams, refer to the appropriate wiring information.  The wiring information includes wiring diagrams, proper wire and connector repair procedures, details of wire harness routing and retention, connector pin-out information and location views for the various wire harness connectors, splices and grounds.

  1. Check the fused B (+) fuse in the Integrated Power Module (TIPM). If OK, refer to  2. If not OK, repair the shorted circuit or component as required and replace the inoperative fuse.
  2. Remove the instrument panel center bezel , disconnect the connector from the back of the 115 V power outlet. Refer to BEZEL, Instrument Panel, Center , Removal and BEZEL, Instrument Panel, Driver Side , Removal . Turn the ignition switch to the RUN position and press the inverter ON switch. Switch the multi-meter from D/C to A/C and check for 115 V at pin 1 and pin 4 in the harness connector. If OK, refer to  3. If not OK, repair the open or short as required.
  3. Replace the 115 V power outlet. Refer to OUTLET, Power, 115 V , Removal .