LEMON Manuals: Even more car manuals for everyone
Home >> Chrysler >> 2011 >> 300 C, RWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 373 ((Heating & Air Conditioning - Electrical Diagnostics - 2500 Hd & 3500 Hd)) >> Diagnosis And Testing >> B11FC-12-Blend Air Sensor Short To Battery >> Diagnostic Test

Diagnostic Test

WARNING: This page is about a different car, the 2013 RAM 3500 HD and 2013 RAM 2500 HD. However, it is still accessible from the selected car via links, so may be relevant.
  1. CHECK IF THE DTC IS ACTIVE 
    1. Ignition on, engine not running.
    2. With the scan tool, read HVAC DTCs.

      Is this DTC active?

      Yes 

      • Go To  2

      No 

      • Go To  6
  2. CHECK THE MIXING CHAMBER TEMPERATURE SENSOR 
    1. Turn the ignition off to the lock position.
    2. Disconnect the Mixing Chamber Temperature Sensor harness connector.
      NOTE:

      Due to the small terminal and pin size of the Mixing Chamber Temperature Sensor and harness connector, make sure to not damage the terminals in this process.

    3. Connect a jumper wire between the (C128) Mixing Chamber Temperature Sensor Signal circuit and the (C121) Sensor Ground circuit in the Mixing Chamber Temperature Sensor harness connector.
    4. Ignition on, engine not running.
    5. With the scan tool, read the Mixing Chamber Temperature Sensor voltage.

      Is the voltage below 0.2 of a volt?

      Yes 

      • Replace the Mixing Chamber Temperature Sensor in accordance with the Service Information..
      • Perform the HVAC VERIFICATION TEST. Refer to STANDARD PROCEDURE .

      No 

      • Go To  3
  3. CHECK THE (C128) MIXING CHAMBER TEMPERATURE SENSOR SIGNAL CIRCUIT FOR A SHORT TO VOLTAGE 
    1. Turn the ignition off to the lock position.
    2. Disconnect the jumper wire from the previous step.
    3. Disconnect the A/C Heater Module C1 harness connector.
    4. Ignition on, engine not running.
    5. Measure the voltage of the (C128) Mixing Chamber Temperature Sensor Signal circuit.

      Is voltage above 0.2 of a volt?

      Yes 

      • Repair the (C128) Mixing Chamber Temperature Sensor Signal circuit for a short to voltage.
      • Perform the HVAC VERIFICATION TEST. Refer to STANDARD PROCEDURE .

      No 

      • Go To  4
  4. CHECK THE (C128) MIXING CHAMBER TEMPERATURE SENSOR SIGNAL CIRCUIT FOR AN OPEN 
    1. Turn the ignition off to the lock position.
    2. Measure the resistance of the (C128) Mixing Chamber Temperature Sensor Signal circuit between the A/C Heater Module C1 harness connector and the Mixing Chamber Temperature Sensor harness connector.

      Is the resistance above 1.0 Ohm?

      Yes 

      • Repair the (C128) Mixing Chamber Temperature Sensor Signal circuit for an open.
      • Perform the HVAC VERIFICATION TEST. Refer to STANDARD PROCEDURE .

      No 

      • Go To  5
  5. CHECK THE (C121) SENSOR GROUND CIRCUIT FOR AN OPEN 
    1. Measure the resistance of the (C121) Sensor Ground circuit between the A/C Heater Module C1 harness connector and the Mixing Chamber Temperature Sensor harness connector.

      Is the resistance above 1.0 Ohm?

      Yes 

      • Repair the (C121) Sensor Ground circuit for an open.
      • Perform the HVAC VERIFICATION TEST. Refer to STANDARD PROCEDURE .

      No 

  6. CHECK THE WIRING AND CONNECTORS 
    1. The conditions necessary to set the DTC are not present at this time.
    2. With the scan tool, check the Environmental Data to help identify the conditions in which the DTC was set.
    3. Using the wiring diagrams as a guide, check all related splices and connectors for signs of water intrusion, corrosion, pushed out or bent terminals, and correct pin tension.
    4. Wiggle the wiring and connectors while checking for shorted and open circuits.

      Were there any problems found?

      Yes 

      No 

      • Test complete.