Diagnostic Test
WARNING: This page is about a different car, the 2013 RAM 3500 HD and 2013 RAM 2500 HD. However, it is still accessible from the selected car via links, so may be relevant.
- CHECK IF DTC IS ACTIVE
- PERFORM HVAC ACTUATOR CALIBRATION TEST
- CHECK THE (C801) MODE DOOR 2 (DEFROST) DRIVER CIRCUIT FOR A SHORT TO VOLTAGE
- Turn the ignition off to the lock position.
- Disconnect the A/C Heater Module C1 harness connector.
- Disconnect the Mode Door 2 Actuator harness connector.
- Ignition on, engine not running.
- Measure the voltage of the (C801) Mode Door 2 Driver circuit.
Is there any voltage present?
Yes
- Repair the (C801) Mode Door 2 (Defrost) Driver circuit for a short to voltage.
- Perform the HVAC VERIFICATION TEST. Refer to STANDARD PROCEDURE .
No
- Go To 4
- CHECK THE (C807) COMMON DOOR DRIVER CIRCUIT 2 FOR A SHORT TO VOLTAGE
- Measure the voltage of the (C807) Common Door Driver 2 circuit.
Is there any voltage present?
Yes
- Repair the (C807) Common Door Driver 2 circuit for a short to voltage.
- Perform the HVAC VERIFICATION TEST. Refer to STANDARD PROCEDURE .
No
- Go To 5
- Measure the voltage of the (C807) Common Door Driver 2 circuit.
- CHECK THE MODE DOOR 2 ACTUATOR
- Turn the ignition off to the lock position.
- Replace the Mode Door Actuator in accordance with the Service Information. Refer to ACTUATOR, MODE DOOR, REMOVAL .
- With the scan tool, erase HVAC DTCs and perform the HVAC Actuator Calibration Test.
Did this DTC reset?
Yes
- Replace and program the A/C Heater Module in accordance with the Service Information. Refer to MODULE, A/C AND HEATER, INSTALLATION .
- Perform the HVAC VERIFICATION TEST. Refer to STANDARD PROCEDURE .
No
- Test complete.
- Perform the HVAC VERIFICATION TEST. Refer to STANDARD PROCEDURE .
- CHECK THE WIRING AND CONNECTORS
- The conditions necessary to set the DTC are not present at this time.
- With the scan tool, check the Environmental Data to help identify the conditions in which the DTC was set.
- Using the wiring diagrams as a guide, check all related splices and connectors for signs of water intrusion, corrosion, pushed out or bent terminals, and correct pin tension.
- Wiggle the wiring and connectors while checking for shorted and open circuits.
Were there any problems found?
Yes
- Repair as necessary.
- Perform the HVAC VERIFICATION TEST. Refer to STANDARD PROCEDURE .
No
- Test complete.