LEMON Manuals: Even more car manuals for everyone
Home >> Chrysler >> 2011 >> 300 C, RWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 217 (6.7L - DTCS P0008 To P040D - 3500 Cab & Chassis) >> Diagnosis And Testing >> P026A-Charge Air Cooler Efficiency Below Threshold >> Set Condition:

Set Condition:

WARNING: This page is about a different car, the 2012 RAM Cab & Chassis. However, it is still accessible from the selected car via links, so may be relevant.

The Powertrain Control Module (PCM) compares the CAC Temperature Sensor reading to a calibrated threshold. The calibrated threshold varies, and is dependant on the reading from the Ambient Air Temperature Sensor. If the CAC Temperature Sensor reading is above the calibrated threshold for a cumulative total of 120 seconds, the PCM determines that the Charge Air Cooler is inefficient. Two trip fault.