LEMON Manuals: Even more car manuals for everyone
Home >> Chrysler >> 2011 >> 300 C, 4WD >> Repair and Diagnosis >> External Pages >> Different car >> Section 973 (6.7L Diesel - DTCS P205E To P245D - 2500 Hd & 3500 Hd) >> Diagnosis And Testing >> P2201-AFTERTREATMENT NOX Sensor Circuit Performance - Bank 1 Sensor 1 >> When Monitored

When Monitored

WARNING: This page is about a different car, the 2015 RAM 3500 HD and 2015 RAM 2500 HD. However, it is still accessible from the selected car via links, so may be relevant.

This diagnostic monitor consists of two separate checks. The first check occurs when the engine exhaust temperature at NOx Sensor 1/1 is above 150°C (302°F), and the engine is in a decel condition with zero fueling. The second check occurs when the engine exhaust temperature at NOx Sensor 1/1 is above 150°C (302°F), and the calculated NOx value is changing.