When Monitored And Set Conditions
WARNING: This page is about a different car, the 2014 RAM 3500 HD and 2014 RAM 2500 HD. However, it is still accessible from the selected car via links, so may be relevant.
When Monitored:
This diagnostic runs continuously when the following conditions are met:
- Engine running.
- Controller voltage between 9.0 and 16.0 volts
- Heated Steering Wheel output is turned on.
Set Conditions:
- Module detects on the Heated Steering Wheel Feed circuit a voltage below 1.5 volts for more than two seconds.
Default Actions:
- When the Heated Steering Wheel is turned on, the ON indicator comes on for 2.0 seconds and then turns off.
- Heated Steering Wheel output is turned off.
| Possible Causes |
|---|
| HEATED STEERING WHEEL FEED CIRCUIT SHORTED TO GROUND |
| HEATED STEERING WHEEL FEED CIRCUIT SHORTED TO THE HEATED STEERING WHEEL RETURN CIRCUIT |
| HEATED STEERING WHEEL (HSW) |
| STEERING COLUMN CONTROL MODULE (SCCM) |
| HEATED SEAT MODULE (HSM) |