Diagnostic Test
- VERIFY ACTIVE DTC NOTE:
Make sure the battery is fully charged.
- Turn the ignition on.
- With the scan tool, read ORC DTCs.
Does the scan tool display active B0001-12-DRIVER FRONTAL SQUIB 1 CONTROL - CIRCUIT SHORT TO BATTERY DTC?
Yes
- Go To 2.
No
- Perform the RESTRAINTS SYSTEM INTERMITTENT TEST. Refer to Standard Procedure .
- CHECK FOR SHORTED SQUIB CIRCUITS IN DRIVER AIRBAG
WARNING:
Turn the ignition off, disconnect the 12-volt battery and wait two minutes before proceeding. Failure to follow these instructions may result in possible serious or fatal injury.
- Disconnect the Driver Airbag Squib harness connectors.NOTE:
Check connectors - Clean and repair as necessary.
- Connect the SRS Load Tool Kit (special tool #8443A, SRS Load Tool) and the SRS Load Tool Jumper (special tool #8443-1, Jumpers, 2 Pin) to the Driver Airbag Squib harness connectors.WARNING:
Turn the ignition on, then reconnect the 12-volt battery and wait two minutes before proceeding. Failure to follow these instructions may result in possible serious or fatal injury.
- With the scan tool, read the ORC DTCs.
Does the scan tool display active B0001-12-DRIVER FRONTAL SQUIB 1 CONTROL - CIRCUIT SHORT TO BATTERY DTC?
Yes
- Go To 3.
No
- Replace the Driver Airbag in accordance with the Service Information.
- Perform the RESTRAINTS SYSTEM VERIFICATION TEST. Refer to Standard Procedure .
WARNING:Turn the ignition off disconnect the 12-volt battery and wait two minutes before proceeding. Failure to follow these instructions may result in possible serious or fatal injury.
- Disconnect the Driver Airbag Squib harness connectors.
- CHECK THE CLOCKSPRING SQUIB CIRCUITS FOR A SHORT TO VOLTAGE
WARNING:
Turn the ignition off, disconnect the 12-volt battery and wait two minutes before proceeding. Failure to follow these instructions may result in possible serious or fatal injury.
- Disconnect the SRS Load Tool Kit (special tool #8443A, SRS Load Tool) and Jumper from the Driver Airbag Squib harness connectors.
- Disconnect the Clockspring C4 harness connector.NOTE:
Check connectors - Clean and repair as necessary.
- Connect the SRS Load Tool Kit (special tool #8443A, SRS Load Tool) and the SRS Load Tool Jumper (special tool #8443-19, 4 Pin Jumper) to the Clockspring C4 harness connector.WARNING:
Turn the ignition on, then reconnect the 12-volt battery and wait two minutes before proceeding. Failure to follow these instructions may result in possible serious or fatal injury.
- With the scan tool, read the ORC DTCs.
Does the scan tool display active B0001-12-DRIVER FRONTAL SQUIB 1 CONTROL - CIRCUIT SHORT TO BATTERY DTC?
Yes
- Go To 4.
No
- Replace the Clockspring in accordance with the Service Information.
- Perform the RESTRAINTS SYSTEM VERIFICATION TEST. Refer to Standard Procedure .
WARNING:Turn the ignition off, disconnect the 12-volt battery and wait two minutes before proceeding. Failure to follow these instructions may result in possible serious or fatal injury.
- CHECK (R43, R45) DRIVER SQUIB 1 CIRCUITS FOR A SHORT TO VOLTAGE
WARNING:
Turn the ignition off, disconnect the 12-volt battery and wait two minutes before proceeding. Failure to follow these instructions may result in possible serious or fatal injury.
- Disconnect the SRS Load Tool Kit (special tool #8443A, SRS Load Tool) and Jumper from the Clockspring C4 harness connector.
- Disconnect the ORC harness connectors.NOTE:
Check connectors - Clean and repair as necessary.
- Connect the SRS Load Tool Adaptor (special tool #8443-24, 32-Way Adapter) to the ORC C2 harness connector.WARNING:
Turn the ignition on, then reconnect the 12-volt battery and wait two minutes before proceeding. Failure to follow these instructions may result in possible serious or fatal injury.
- Measure the voltage of the (R43) Driver Squib 1 Line 2 circuit between the Clockspring C4 harness connector cavity 4 and ground.
- Measure the voltage of the (R45) Driver Squib 1 Line 1 circuit between the Clockspring C4 harness connector cavity 3 and ground.
Is there any voltage present for either measurement?
Yes
- Repair the (R43, R45) Driver Squib 1 circuits for a short to voltage.
- Perform the RESTRAINTS SYSTEM VERIFICATION TEST. Refer to Standard Procedure .
WARNING:Turn the ignition off, disconnect the 12-volt battery and wait two minutes before proceeding. Failure to follow these instructions may result in possible serious or fatal injury.
No
- Replace the ORC in accordance with the Service Information.
- Perform the RESTRAINTS SYSTEM VERIFICATION TEST. Refer to Standard Procedure .
WARNING:Turn the ignition off, disconnect the 12-volt battery and wait two minutes before proceeding. Failure to follow these instructions may result in possible serious or fatal injury.
WARNING:If the Occupant Restraint Controller (ORC) is dropped at any time, it must be replaced. Failure to follow these instructions may result in possible serious or fatal injury.