LEMON Manuals: Even more car manuals for everyone
Home >> Chrysler >> 2010 >> Sebring Convertible V6-2.7L >> Repair and Diagnosis >> Body and Frame >> Doors, Hood and Trunk >> Trunk / Liftgate >> Power Trunk / Liftgate Lock Actuator >> Testing and Inspection

Power Trunk / Liftgate Lock Actuator: Testing and Inspection






DECKLID RELEASE SOLENOID

1. Confirm motor lead wire is connected and 10 volts or more are available at solenoid.
2. Provide proper ground through latch mounting screws.
3. Remove latch and examine plunger. Plunger should spring back when pressed.
4. Insure that solenoid plunger travel is adequate approximately 16 mm (5/8 inch).