LEMON Manuals: Even more car manuals for everyone
Home >> Chrysler >> 2009 >> Sebring Convertible V6-3.5L >> Repair and Diagnosis >> Powertrain Management >> Emission Control Systems >> Air Injection >> Air Injection Hose/Tube >> Service and Repair >> Removal

Removal






REMOVAL





1. Cut the tie straps (3) being careful not to damage the air inlet tube (4).
2. Remove the constant tension clamp (2) and remove the mass air flow (MAF) sensor (1) from the air inlet tube (4). Position MAF sensor (1) and wiring aside.





3. Remove air inlet tube (3) by pushing the ends (1) together, while pulling the air inlet tube (3) away from air pump housing connection (2).