Diagnostic Test
- TEST FOR INTERMITTENT CONDITION
- With the scan tool, record and erase DTC's
- Operate the Liftgate or Decklid release several times.
- Cycle the ignition from on to off.
- Turn the ignition on.
- With the scan tool, read DTC's.
Does the scan tool display B1828-TRUNK/GATE RELEASE CONTROL CIRCUIT PERFORMANCE?
Yes
- Go to step 2
No
- The conditions that caused this code to set are not present at this time. Using the SYSTEM WIRING DIAGRAMS as a guide, inspect the wiring and connectors.
- Perform the BODY VERIFICATION TEST. Refer to DTC-Based Diagnostics/MODULE, Totally Integrated Power (TIPM) - Standard Procedure
- (P31) DECKLID/LIFTGATE RELEASE DRIVER CIRCUIT SHORT TO GROUND
- Turn the ignition off.
- Disconnect the Instrument Cluster C1 connector.
- Measure the resistance between ground and the (P31) Decklid/Liftgate Release Driver circuit in the Cluster C1 connector.
Is the resistance below 1.5 ohms?
Yes
- Repair the (P31) Decklid/Liftgate Release Driver circuit for a short to ground.
- Perform the BODY VERIFICATION TEST. Refer to DTC-Based Diagnostics/MODULE, Totally Integrated Power (TIPM) - Standard Procedure
No
- Go to step 3
- (P31) DECKLID/LIFTGATE RELEASE DRIVER CIRCUIT SHORTED TO BATTERY
- Turn the ignition on.
- Measure the voltage between ground and the (P31) Decklid/Liftgate Release Driver circuit in the Cluster C1 connector.
Is there any voltage present?
Yes
- Repair the (P31) Decklid/Liftgate Release Driver circuit for a short to voltage.
- Perform the BODY VERIFICATION TEST. Refer to DTC-Based Diagnostics/MODULE, Totally Integrated Power (TIPM) - Standard Procedure
No
- Go to step 4
- (P31) DECKLID/LIFTGATE RELEASE DRIVER CIRCUIT OPEN
- Turn the ignition off.
- Disconnect the Decklid/Liftgate Latch connector.
- Measure the resistance of the (P31) Decklid/Liftgate Release Driver circuit between the Cluster C1 connector and the Decklid/Liftgate Latch connector.
Is the resistance above 5.0 ohms?
No
- Repair the (P31) Decklid/Liftgate Release Driver circuit for an open.
- Perform the BODY VERIFICATION TEST. Refer to DTC-Based Diagnostics/MODULE, Totally Integrated Power (TIPM) - Standard Procedure
Yes
- Replace the Decklid or Liftgate Latch in accordance with service information.
- Perform the BODY VERIFICATION TEST. Refer to DTC-Based Diagnostics/MODULE, Totally Integrated Power (TIPM) - Standard Procedure