LEMON Manuals: Even more car manuals for everyone
Home >> Chrysler >> 2009 >> PT Cruiser Limited >> Repair and Diagnosis >> External Pages >> Different car >> Section 13 (Heating & Air Conditioning (Service Information)) >> Plumbing >> Diagnosis And Testing >> Refrigerant System Leaks >> System Empty

System Empty

WARNING: This page is about a different car, the 2009 Dodge Caliber. However, it is still accessible from the selected car via links, so may be relevant.
  1. Evacuate the refrigerant system to the lowest degree of vacuum possible (approximately -88 kPa (-26 in. Hg) or greater vacuum). See Heating and Air Conditioning/Plumbing - Standard Procedure . Determine if the system holds a vacuum for 15 minutes. If vacuum is held, a leak is probably not present. If system will not maintain vacuum level, proceed to  2.
  2. Prepare and dispense 0.284 kilograms (10 ounces) of R-134a refrigerant into the evacuated refrigerant system. See Heating and Air Conditioning/Plumbing - Standard Procedure  and proceed to  1 of the System Low procedure.