Possible Causes
| Possible Causes |
|---|
| (F855) 5-VOLT SUPPLY CIRCUIT OPEN |
| (F855) 5-VOLT SUPPLY CIRCUIT SHORTED TO GROUND |
| (K44) CMP SIGNAL CIRCUIT SHORTED TO BATTERY VOLTAGE |
| (K44) CMP SIGNAL CIRCUIT OPEN |
| (K44) CMP SIGNAL CIRCUIT SHORTED TO GROUND |
| (K44) CMP SIGNAL CIRCUIT SHORTED TO (F855) 5-VOLT SUPPLY |
| TONE WHEEL/PULSE RING |
| CAMSHAFT POSITION SENSOR |
| POWERTRAIN CONTROL MODULE (PCM) |
Always perform the Pre-Diagnostic Troubleshooting procedure before proceeding. See DTC-Based Diagnostics/MODULE, Powertrain Control (PCM) - Standard Procedure .