No Response From Orc (Occupant Restraint Controller): Notes
For complete wiring diagrams, refer to SYSTEM WIRING DIAGRAMS .
| Possible Causes |
|---|
| (Z911) GROUND CIRCUIT OPEN |
| (F100) FUSED IGNITION SWITCH OUTPUT (RUN) CIRCUIT OPEN OR SHORTED |
| (F200) FUSED IGNITION SWITCH OUTPUT (RUN/START) CIRCUIT OPEN OR SHORTED |
| (D55) AND (D54) CAN B BUS CIRCUITS OPEN |
| OCCUPANT RESTRAINT CONTROLLER MODULE |