LEMON Manuals: Even more car manuals for everyone
Home >> Chrysler >> 2009 >> PT Cruiser L4-2.4L >> Repair and Diagnosis >> A L L Diagnostic Trouble Codes ( DTC ) >> Testing and Inspection >> B Code Charts >> B10E9

B10E9






B10E9-BLOWER MOTOR CONTROL CIRCUIT LOW





For a complete wiring diagram, refer to the Wiring Information Electrical Diagrams.

- When Monitored:
With the ignition on.

- Set Condition:
If the Totally Integrated Power Module (TIPM) detects an excessive current draw on the (C70) Blower Motor Control circuit for 20 micro seconds when blower motor operation is requested.





1. VERIFY DTC B10E9-BLOWER MOTOR CONTROL CIRCUIT LOW IS ACTIVE
1. Turn the blower control switch to off.
2. Turn the ignition off, wait 10 seconds, and turn the ignition on.
3. With the scan tool, erase TIPM DTCs.
4. Turn the ignition off, wait 10 seconds, and turn the ignition on.
5. Turn the blower control switch to on.
6. With the scan tool, read TIPM DTCs.

Does the scan tool display active: B10E9-BLOWER MOTOR CONTROL CIRCUIT LOW?

Yes

- Go To 2

No

- Check for an intermittent condition by inspecting the related wiring harness for chafed, pierced, pinched, and partially broken wires. Also, inspect the related connectors for broken, bent, corroded, or contaminated terminals.
- Perform the BODY VERIFICATION TEST. Body Verification Test

2. CHECK FOR ACTIVE DTC B10E9-BLOWER MOTOR CONTROL CIRCUIT LOW WITH BLOWER MOTOR HARNESS CONNECTOR DISCONNECTED




1. Turn the blower control switch to off.
2. Disconnect the Blower Motor harness connector.
3. Turn the ignition off, wait 10 seconds, and turn the ignition on.
4. With the scan tool, erase TIPM DTCs.
5. Turn the ignition off, wait 10 seconds, and turn the ignition on.
6. Turn the blower control switch to on.
7. With the scan tool, read TIPM DTCs.

Does the scan tool display active: B10E9-BLOWER MOTOR CONTROL CIRCUIT LOW?

Yes

- Go To 3

No

- Replace the Blower Motor.
- Perform the BODY VERIFICATION TEST. Body Verification Test

3. CHECK THE (C7) BLOWER MOTOR CONTROL CIRCUIT FOR A SHORT TO GROUND




1. Turn the ignition off.
2. Disconnect the TIPM C8 harness connector.
3. Measure the resistance of the (C7) Blower Motor Control circuit between ground and the Blower Motor harness connector.

Is the resistance below 10k ohms?

Yes

- Repair the (C7) Blower Motor Control circuit for a short to ground.
- Perform the BODY VERIFICATION TEST. Body Verification Test

No

- Replace the TIPM.
- Perform the BODY VERIFICATION TEST. Body Verification Test